Lanbo · every tool for heat exchanger, condenser & boiler work · 103 products →中文WhatsApp our sales teamTel +86 551 6288 4258Email Lanbo@hflanbo.com.cn
Home / Guides

Choosing a Hydraulic Tube Puller: Collet vs Screw Type Guide

How to choose a hydraulic tube puller: collet vs screw type, rated pull force and tube size range, comparing Lanbo YKB-4, YKB-5, YKB-6, QBG-F and LSB-2 models.

Choosing a Hydraulic Tube Puller: Collet vs Screw Type Guide

A tube puller has one job: grip the tube stub left in the tubesheet and pull it out along its axis without damaging the hole. Choosing one comes down to four questions: how the puller grips the tube, how much force it can apply, which tube sizes it covers, and how it is powered.

This guide compares Lanbo's tube pullers on those points, using the ratings published for each model.

Lanbo crew working on a heat exchanger tubesheet

Before choosing: cut, then pull

A puller works on a tube that has already been cut free inside, usually just behind the tubesheet with an internal cutter such as the DNQ-A, or at a support plate with the DNQ-B. Pulling a short stub needs much less force than dragging a full-length tube through the hole, and it keeps the load off the ligaments. Driving tubes out with a collapsing tool on a demolition hammer is not a substitute: the impact can damage tube holes and tube-to-tubesheet welds, and that damage is usually irreversible.

Collet type vs screw type

Screw type

A screw-type puller uses a threaded spear that is turned into the tube ID, cutting its own thread in the tube wall. The thread gives a positive grip, which helps on tubes that are tight in the hole, fouled, or rolled hard. Setting the spear takes a little more time per tube, and the spear has to match the tube ID: too small and the thread can strip; too large and it can load the hole.

Lanbo screw-type models:

Spears: the Tube Puller Head, Screw Type covers tube OD φ7.94–φ32 mm and wall 0.4–2.5 mm (BWG 13–27).

Collet type

A collet-type puller inserts a collet into the tube and expands it to grip the wall. It is quicker to set and release, which helps when pulling large numbers of tubes of the same size. Grip depends on the collet matching the tube ID and on the tube condition, so heavily fouled or thin, soft tubes need a check before production pulling.

Lanbo collet-type models:

YKB-5 hydraulic tube puller, collet type

Quick comparison

Point Screw type Collet type
Grip Thread cut into tube wall Expanding collet
Set-up per tube Slower Faster
Tight or fouled tubes Usually more secure grip Check grip on a trial tube
Lower OD limit in YKB range φ12 mm (YKB-4) φ16 mm (YKB-5, YKB-6-2)

Pull force

The pull force needed depends on tube material, OD and wall, joint type (rolled, welded, rolled and welded), the length of the stub and the degree of fouling or corrosion. There is no single number that fits every unit.

In practice:

Tube size

Match the puller and spear to the tube OD and wall:

Power source

Hydraulic

The YKB series is hydraulic. A compact gun (2.2 kg) works at the tubesheet face, which matters when working inside a condenser waterbox for long shifts.

Electric

The QBG-F Electric Tube Puller covers tube OD φ15–φ28 mm with a rated pull of 4200 kgf and a 5.2 kg gun. It suits sites where an electric supply is easier to arrange than a hydraulic set-up.

Manual

The LSB-2 Manual Tube Puller covers tube OD φ12–φ32 mm, wall 0.5–2 mm, in copper, stainless, titanium and carbon steel. It suits small jobs, spot retubes and locations without power.

Worker inside a condenser waterbox working on tube ends

Lanbo tools for this job

Not sure which puller fits your unit? Send us the tube material, OD × wall thickness, tube count and joint type, and we will suggest a puller, spear and cutter set. Request a quote.

FAQ

Can one puller cover several tube sizes?

Yes, within its range. The gun stays the same and the spear or collet is changed to match each tube size. Order spears for each OD and wall you expect to pull.

Is a higher pull rating better?

Not by itself. A rating that matches the stub you are pulling is enough. If a well-cut stub needs more than the rated pull, check the cut and grip before anything else.

Which type is better for titanium or stainless tubes?

It depends on wall thickness and how tight the tubes are. Screw-type spears usually give a secure grip on hard tubes; spear size and tube wall need to match. Send us the tube data and we will advise.

Do I need a separate hydraulic pump?

The YKB series is hydraulic and needs a hydraulic supply; ask us about the pump configuration for the model you choose. The QBG-F is electric and the LSB-2 is manual.

Request a quote

Tell us the tube material, OD × wall and quantity. We usually reply within one working day.